LV Cast Resin Dry Type Transformers (CRT)
Self-extinguishing low-voltage dry-type transformers, with coils cast in epoxy resin, for moisture-prone and polluted environments. Cores made with cold-rolled grain-oriented silicon steel sheets. Optional protective enclosures available for outdoor applications.
-
MV Cast Resin Dry Type Transformers (CRT)
Self-extinguishing medium-voltage dry-type transformers, with coils cast in epoxy resin, for moisture-prone and polluted environments. Cores made with cold-rolled grain-oriented silicon steel sheets. Optional protective enclosures available for outdoor applications.
-
Low-Voltage Dry-Type Transformers
DTH Series
LV Dry-Type Transformers, made with high-permeability cold-rolled grain-oriented silicon steel sheets (CRGO) and H-Class insulating materials, are self-extinguishing and characterized by excellent dissipation of heat, high efficiency, low noise, easy installation, and low maintenance.
-
Pad-Mounted Transformers
OSA Series (Padmount)
CIC Pad-Mounted Transformers have been used by the Taiwan Power Company for over 25 years. These products, well-received in numerous countries, are type-tested by CIC's internationally-accredited testing laboratory.
-
Epoxy Insulator Accessories for Medium-Voltage C-GIS
Epoxy resin insulator accessories play a crucial role in C-GIS, which is short for cubicle-type gas-insulated switchgear—a type of gas-insulated switchgear (GIS). These insulator accessories are integral to the metal-enclosed switchgear equipment that is insulated with sulfur hexafluoride (SF6) gas.
-
Overvoltage Protector for Current-Transformer Protection
CCTP-03
When a power system is in operation, it is imperative that the secondary of the current transformer(s) should not have an open circuit. When an open circuit occurs, an extremely high transient voltage will be induced, which can in turn damage the current transformers and the instruments at the secondary, or even posing a threat to personal safety. This CT secondary overvoltage protector offers protection from such accidental damage caused by secondary transient voltage.
-
Multi-Channel Electronic Energy Meter
CED-4C ML
For multi-channel measurements, this advanced multifunction energy meter comprises 4 modules within one energy meter. RS485 Modbus Communion is provided through 2 x RJ45 connectors.
-
Split-Core Current Sensors C06 Series
C06-05E, C06-10E, C06-15E, C06-20E, C06-25E
Hinged clip and compact design for easy installation. Current input range: 5 A – 25 A.
-
Split-Core Current Sensors C10 Series
C10-15E, C10-30E, C10-50E, C10-60E, C10-75E
Hinged clip and compact design for easy installation. Current input range: 15 A – 75 A.
-
Split-Core Current Sensors C16 Series
C16-50E, C16-80E, C16-100E, C16-120E, C16-150E
Hinged clip and compact design for easy installation. Current input range: 50 A – 150 A.
-
Split-Core Current Sensors C24 Series
C24-100E, C24-150E, C24-200E, C24-250E, C24-300E
Hinged clip and compact design for easy installation. Current input range: 100 A – 300 A.
-
Split-Core Current Sensors C36 Series
C36-200E, C36-300E, C36-400E, C36-500E, C36-600E
Hinged clip and compact design for easy installation. Current input range: 200 A – 600 A.
-
Current Sensors With Lead Wire Output
CO06, CO07, CO09, CO13, CO15, CO20, CO26
CO Series Current Sensors, with two wire leads for connection. Current input range: from 5 A to 600 A.
-
PCB-Mounting Current Sensors (5 A ~ 25 A)
CU05
PCB Mount Type Current Sensors. Primary Current: 5 A ~ 25 A.
-
PCB-Mounting Current Sensors (5 A ~ 150 A)
CU07, CU09, CU13
PCB Mount Type Current Sensors. Primary Current: 5 A ~ 150 A.
-
Digital Tester (Comparator) for Instrument Transformers
WHES-1Cx
Digital Tester (Comparator) for Instrument Transformers is designed for the testing of ratio error and phase displacement of current transformers and voltage transformers (potential transformers).
-
Standard Potential Transformers (Voltage Transformers)
WHJB Series
WHJB Series Standard Potential Transformers are mainly used as reference PTs (VTs) in a variety of potential (voltage) transformer tests: error tests, characteristic tests, and so on.
-
Standard Current Transformers
WHLB Series
WHLB Series Standard Current Transformers are mainly used as reference CTs for current transformer measurements and tests: error tests, characteristic tests, and so on.
-
Burden for Current Transformer
WFY 47, 49 & 47-49
Burden for Current Transformer is mainly used for loading a CT during testing. Available in several structural designs for use in a variety of testing environments, this Burden for Current Transformer is compliant with IEC 60044-1 or ANSI/IEEE C57.13. Customer specifications can also be requested to satisfy different requirements.
-
Burden for Potential Transformer (Voltage Transformer)
WFY 95
Burden for Potential Transformer is mainly used as the secondary load of a PT (VT) during testing. Available in several structural designs for use in various testing environments, this Burden for Potential Transformer is compliant with IEC 60044-1 or ANSI/IEEE C57.13. Customer specifications can also be requested to satisfy different requirements.
-
Instrument Transformer Testing System
WHES Series
WHES Series Instrument Transformer Testing System is designed to measure various properties of electromagnetic current transformers and potential transformers (voltage transformers).
-
Current Transformers (CT) - Instrument Transformers
Current transformers, abbreviated as CT, are specialized transformers used in AC electrical circuits. Together with voltage transformers (VT), they are collectively known as "instrument transformers." Current transformers function by transforming higher current (I1) on their primary side into lower current (I2) on their secondary side, maintaining a specific ratio. Typically, the secondary current is transformed into 5A or 1A, as prescribed by current IEC and IEEE regulations. The transformed current can be easily and safely measured, serving the purpose of monitoring and measuring electricity consumption in circuits and systems. Current transformers can also play a crucial role in providing protection to the primary side electrical circuits.
-
Low-Voltage (LV) Current Transformers (CT) 0.72 kV max.
Low-voltage current transformers by CIC are manufactured in two main insulation styles: ABS-encased or cast-resin types. In terms of structure, the LV current transformer series offers different variations, including window-type and split-core models. Functionally, there are two main types: metering (measurement) CTs and protection CTs. There are also zero-phase current transformers (ZCTs) suitable for outdoor or indoor use by utility companies or high-voltage end-users to protect against high-voltage power cable leakage and support other monitoring needs. This product line also includes special types, such as dry-type bushing current transformers (BCT), ideal for GIS switches or transformer bushings. All types and specifications of current transformers from CIC undergo type tests and routine tests conducted by CIC's Advanced Electricity Lab, accredited by the ILAC member TAF, ensuring product quality. With over 45 years of professional experience, CIC manufactures a wide range of high-quality and versatile current transformers. Our diverse product specifications cater to the needs of various customer groups. We also offer customization and ODM/OEM services. Due to the high precision and stable quality of our products, they are widely adopted in billing, power supply, and distribution projects by utility companies, factories, major engineering ventures, and construction companies worldwide.
-
Medium-Voltage (MV) Current Transformers (CT) 3.6-7.2 kV
Current Transformers 3.6-7.2 kV Series are primarily used for measurement, monitoring, or protection in motor control panels and other equipment. Models include single/double core epoxy resin CTs, coil molded CTs, terminal type, window type, and more. The main insulation material is Huntsman (formerly Ciba-Geigy of Switzerland) Araldite® epoxy resin. Current transformers can be manufactured according to IEC, IEEE, or other standards. Outdoor current transformers are also available per customer requirements. Type tests and routine tests for CIC’s medium-voltage current transformers are all conducted by CIC's Advanced Electricity Lab, accredited by ILAC member TAF, ensuring quality. With decades of experience, CIC manufactures current transformers in a wide variety of specifications to meet diverse customer needs, also offering customization and ODM/OEM services. Thanks to high accuracy and reliable quality, CIC's products are widely used for metering and distribution by utilities, factories, major projects and builders globally.
- Home Main Page
- About Us The Company
-
Products Featured Categories
- Current Transformers (CT) - Instrument Transformers
- Voltage Transformers / Potential Transformers (VT/PT) - Instrument Transformers
- Low-Voltage (LV) Voltage Transformers / Potential Transformers & Control Transformers 0.72 kV max.
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 3.6-7.2 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 12-24 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 36 kV
- Instrument Transformer (CT & VT/PT) Testing Equipment
- Distribution Transformers (LV & MV)
- Low-Voltage Power Capacitors & Capacitor Banks
- Electrical Reactors & Autotransformer Starter
- Epoxy Resin Insulators & Epoxy Bushings
- Voltage Monitors & Overvoltage Protectors
- Current Sensors
- Electronic Energy Meters / Electricity Meters
- EV Charging Stations / Electric Vehicle Chargers
- Surge Protection Devices (SPD)
- Newsroom Latest Information
- Contact Customer Service