Air Core Reactors
These MV air-core reactors are single-phase dry-type series reactors which are mainly used together with 12 kV or 24 kV capacitor banks in electrical substations of utility companies. The insulation shell of the product is molded in epoxy resin. To reduce core loss and noise, this type of self-cooling detuned reactor utilizes the air-core design and construction. Besides having excellent insulation and moisture resistance, these air-core reactors can withstand large short-circuit current, are easy to maintain, and offer great durability.
-
MV Dry-Type Motor-Starting Reactor / Motor-Starting Autotransformer (Compensator)
The Motor Starting Reactor or Motor Starting Autotransformer (Compensator) is economical and maintenance free. This medium-voltage dry-type motor starter can be made according to customers' specific requirements.
-
Medium-Voltage Series Reactors (Detuned Reactors)
MV Dry-Type Series Reactors (detuned reactors) with ratings ranging from 3.6 kV to 24 kV have coils that are insulated with Class-H materials and then coated with epoxy resin. The three phases are insulated against each other by the air within the space between them. These electrical reactors are noted for their moisture resistance, excellent heat dissipation, low noise, easy maintenance, and product longevity.
-
Low-Voltage Series Reactors (Detuned Reactors)
XDTH Series
Detuned reactors, connected in series, are necessary for circuits with high harmonic currents. These “series reactors,” usually part of a power factor correction (PFC) capacitor bank, help to reduce harmonics in currents, increase power efficiency, and prevent disasters caused by resonance.
-
Electrical Reactors & Autotransformer Starter
Electrical reactors have been a cornerstone of CIC’s product lines since 1985. Leveraging decades of expertise in product design, development, and manufacturing, CIC proudly presents a versatile range of low-voltage and medium-voltage detuned reactors (series reactors), encompassing both iron-core and air-core variations. CIC’s dry-type electrical reactors fall into two primary categories: some are insulated with Class-H materials, such as Nomex, while others utilize epoxy-resin insulation. Notably, except for the air-core models, the reactor cores are divided into sections to ensure linear inductance.
- Home Main Page
- About Us The Company
-
Products Featured Categories
- Current Transformers (CT) - Instrument Transformers
- Voltage Transformers / Potential Transformers (VT/PT) - Instrument Transformers
- Low-Voltage (LV) Voltage Transformers / Potential Transformers & Control Transformers 0.72 kV max.
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 3.6-7.2 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 12-24 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 36 kV
- Instrument Transformer (CT & VT/PT) Testing Equipment
- Distribution Transformers (LV & MV)
- Low-Voltage Power Capacitors & Capacitor Banks
- Electrical Reactors & Autotransformer Starter
- Epoxy Resin Insulators & Epoxy Bushings
- Voltage Monitors & Overvoltage Protectors
- Current Sensors
- Electronic Energy Meters / Electricity Meters
- EV Charging Stations / Electric Vehicle Chargers
- Surge Protection Devices (SPD)
- Newsroom Latest Information
- Contact Customer Service