Two-Core Rectangular-Window Current Transformer - Resin Encapsulated - Low Voltage - Indoor
ES-1S-B Series
Rectangular current transformers of the ES-1S-B series are dual-core (double-core) window-type models for versatile installation. The two-core design makes this a dual-purpose CT, allowing simultaneous use with measurement devices and protective relays per IEC/IEEE low voltage standards (720 volts / 600 volts, or 0.72 kV / 0.6 kV). Resin insulation delivers water resistance and self-extinguishing properties. These current transformers withstand 40x thermal current for 1 second. A choice of mounting accessories is included.
-
Split-Core Rectangular-Window Current Transformer - Resin Encapsulated - Low Voltage - Indoor
ES-1S-C Series
Our split-core, rectangular-window current transformers from the ES-1S-C Series are resin-encapsulated for water resistance and self-extinguishing properties. These single-core current transformers work with protective relays or measurement instruments to monitor current flow per IEC/IEEE low voltage standards (720 volts / 600 volts, or 0.72 kV / 0.6 kV). Window-type design splits open without removing wiring for simple mounting on existing systems. Thermal withstand is 40x nominal current for 1 second. A choice of accessories helps simplify mounting and installation.
-
Bushing Current Transformers for 23 kV C-GIS
EO1M6, EO1M20, EO1M150
These epoxy-cast multi-ratio bushing current transformers (BCTs, or bushing CTs) are typically installed in 23 kV C-GIS (cubicle-type gas-insulated switchgear) for use with measuring or monitoring instruments, or protective relays.
-
Zero-Phase Current Transformers (ZCT) for Ground-Fault Protection
EZ Series
Designed to protect the power system against leakage and earth faults, these zero-phase current transformers (ZCT) come in various window diameters. Epoxy-cast coil.
-
Low-Voltage Ring-Core Protective-Type Current Transformer for Outdoor Use (Epoxy-Cast)
EO1MC20R
Outdoor, ring-core (window-type) protective (or monitoring) current transformer for power companies or HV power systems. Converting high AC currents into signals to be received by the relay. Cycloaliphatic Epoxy.
-
Low-Voltage Split-Core Protective-Type Current Transformer for Outdoor Use (Epoxy-Cast)
EO1MD20
Window-type (split-core), outdoor, protective (or monitoring) current transformer for power companies or HV power systems. Converting high AC currents into signals to be received by the relay. Cycloaliphatic Epoxy.
-
Dry-Type Bushing Current Transformers for GIS or Power Transformers
TB-1M Series
Suited to power transmission and distribution systems and intended to work with measuring or monitoring instruments, or with protective relays, these bushing CTs (BCTs) can also be used with GIS or in conjunction with power transformers bushings. Insulation tape or epoxy resin as insulation material.
-
3.6 kV / 7.2 kV Current Transformers (1-Core / 2-Core & Single-Ratio / Dual-Ratio Options)
CR-3(6)S-T Series
Intended for the main panel or the motor control panel of a 3.6/7.2 kV power system and designed to be used with measuring or monitoring instruments, or with protective relays. Each CT has a busbar terminal. Insulated with Araldite® epoxy resin.
-
3.6 kV Two-Core Epoxy-Cast Current Transformer
ER-3C
Offering a higher rated current ratio, this medium-voltage, two-core current transformer is suited to the main panel or the motor control panel of a 3.6 kV (max.) power system and can be used with measuring or monitoring instruments, or with protective relays. Araldite® epoxy resin.
-
12 kV Two-Core Current Transformers
EWF-10D Series
2-core current transformers designed for 12 kV (max.) power systems for use with measuring (or monitoring) instruments and protective relays, these products are cast in Araldite® epoxy and meet the requirements of all major electrical standards.
-
24 kV Epoxy-Cast Current Transformers for Indoor Application
EWF-20DA, EWF-20DB, EWF-20DD, EWF-20DE, EWF-20DS
For use in conjunction with energy meters or protective relays. Available in single-core, 2-core, and 3-core models. Insulated with Araldite® epoxy resin. Custom-made to meet various requirements.
-
24 kV Two-Core Current Transformer (“U-Shaped Top” Design)
EWF-20DI
2-core epoxy-cast current transformer for a 24 kV (max.) power system. For use with measuring or monitoring instruments, and protective relays. “U-shaped top” design for safety and for a shorter distance between two current transformers installed side-by-side, thus reducing the required width of the switchgear panel.
-
24 kV Two-Core Current Transformer (for Polluted Regions)
EWF-20DK
2-core current transformer for a 20~24kV power system. Used in conjunction with measuring or monitoring instruments, and with protective relays. Epoxy cast. Designed to have greater creepage, it is appropriate for polluted regions.
-
Multi-Ratio Current Transformers (Single-Core & Two-Core Options) for 25 kV max. Power Systems
CR-20S Series
Current transformers for installation in a switchgear panel of a 25kV (max.) power system and to be used with measuring or monitoring instruments, or protective relays. These are economic models suited to locations of high humidity or moderate pollution. The insulation material for the core and the secondary coil is Araldite® epoxy resin.
-
Bushing Current Transformers for Draw-Out Circuit Breakers
HCB-2415(A), EBF-25M Series
Multi-ratio bushing current transformers (bushing CTs, or BCTs) designed for 24kV draw-out circuit breakers and to be used with measuring (or monitoring) instruments or protective relays. IEEE 0.3 B-0.9. Cast in Araldite® epoxy.
-
36 kV Multi-Ratio Current Transformers (Indoor Use)
EWF-30D Series
Suited to ≤ 36kV power systems, these multi-ratio current transformers are available in 2-core and 3-core options. Insulated with Araldite® epoxy and intended to work with measuring or monitoring instruments, or with protective relays.
-
Three-Phase Grounding Voltage Transformer (GVT), or Grounding Potential Transformer (GPT), for MV Indoor Applications
EGP-3DF, EGP-6DF
This ground voltage transformer (GVT), or ground potential transformer (GPT), is a three-phase medium-voltage (MV) potential transformer for indoor applications. With a fuse for each phase, this PT (VT) features epoxy-insulated coils and a five-legged (five-limbed) laminated core. This voltage transformer is used with measuring or monitoring instruments, or for ground-fault protection.
-
Single-Pole Voltage Transformers (Potential Transformers), or Three-Phase VT (PT) + GVT (GPT)
EPF-10CE, EPF-10DE, EPF-20SK, EPF-20SL, EPF-30DE
Voltage transformers from this series are indoor medium-voltage single-phase epoxy-resin-cast potential transformers suitable for 12kV, 24kV, and 36kV power systems. They are used in conjunction with measuring instruments for system monitoring and analysis or in combination with protective relays. Specific models can be equipped with a combination fuse assembly on the primary side. Additionally, models with a maximum thermal burden of 1000 VA can also function as a power source for circuit breaker operation, meaning they can serve as "control power transformers" or "control transformers," also known as CPT or CTR, or "industrial control transformers" or "machine tool transformers."
-
Overvoltage Protector for Current-Transformer Protection
CCTP-03
When a power system is in operation, it is imperative that the secondary of the current transformer(s) should not have an open circuit. When an open circuit occurs, an extremely high transient voltage will be induced, which can in turn damage the current transformers and the instruments at the secondary, or even posing a threat to personal safety. This CT secondary overvoltage protector offers protection from such accidental damage caused by secondary transient voltage.
- Home Main Page
- About Us The Company
-
Products Featured Categories
- Current Transformers (CT) - Instrument Transformers
- Voltage Transformers / Potential Transformers (VT/PT) - Instrument Transformers
- Low-Voltage (LV) Voltage Transformers / Potential Transformers & Control Transformers 0.72 kV max.
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 3.6-7.2 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 12-24 kV
- Medium-Voltage (MV) Voltage Transformers / Potential Transformers 36 kV
- Instrument Transformer (CT & VT/PT) Testing Equipment
- Distribution Transformers (LV & MV)
- Low-Voltage Power Capacitors & Capacitor Banks
- Electrical Reactors & Autotransformer Starter
- Epoxy Resin Insulators & Epoxy Bushings
- Voltage Monitors & Overvoltage Protectors
- Current Sensors
- Electronic Energy Meters / Electricity Meters
- EV Charging Stations / Electric Vehicle Chargers
- Surge Protection Devices (SPD)
- Newsroom Latest Information
- Contact Customer Service